1. PTMS magnetic separator The motor is overheating and its sound is abnormal.

The reasons for the overheating of the magnetic separator and its abnormal sound are as follows: 1. The bearing is poorly lubricated or seriously worn; 2. The fan blade is removed or worn. 3. Poor contact of the switch line, or break the line to run single-phase; 4. The voltage is too low.

2.PTMS magnetic separator overheating

The reasons are: 1. insufficient oil or poor oil quality; 2. Gear and worm wear too much, or meshing is not good; 3. Bearing poor lubrication or serious wear.


PTMS magnetic separation

3.PTMS magnetic separator sounds abnormal during operation, the cylinder is stuck by obstacles, and even the cylinder cannot be rotated and the bottom box vibrates.

The reason is often stuck by the object of the bottom box, and then the magnetic block falls off, making the cylinder rattle, and the shell will be scratched seriously. At this time should stop maintenance, troubleshooting.


what is magnetic separation in Kaolin?

If any of the conditions change and PTMS magnetic separator equipment is still produced at the normal operating rate, it will affect the normal magnetic separation operation. Therefore, the magnetic separator operator should maintain contact with the upper and lower processes to achieve a mature understanding of the overall production.

Contact: DELLA

Mob: +86-13929907491

sales@powtechina.com


FOSHAN POWTECH TECHNOLOGY COMPANY LIMITED.

No.9, Factory 2, Shijin Industry Park, Shishan Town, Nanhai District, Foshan City, Guangdong, China
Ph: +86-13929907491
E-mail: Sales@powtechina.com

QR code

Copyright © Foshan Powtech Technology Company Limited. All Rights Reserved.   Sitemap   XML