Wet PTMS MAGNETIC SEPARATOR If the magnetic system deflection Angle is not appropriate, it will obviously affect the separation index. The so-called magnetic declination Angle is the Angle between the center line of the magnetic system arc and the vertical line of the cylinder center. The working gap of the wet weak magnetic field permanent magnet drum separator refers to the distance between the shell and the bottom plate, and the pulp passes through the gap, which is also the effective area of the magnetic field, and its thickness can be adjusted between 30 and 60mm.
PTMS MAGNETIC SEPARATOR Too large or too small working gap will affect the separation index. The suitable value of the working gap should be determined according to the specific production situation of each factory, and the adjustment method is to add or reduce gaskets on the four fulcrums of the frame support tank. Because the position of the cylinder is fixed, the tank body is raised after the gasket is added, and the working gap becomes smaller; Reduce the gasket, the working gap is larger.
PTMS MAGNETIC SEPARATOR The size of the working gap should be uniform along the axial direction. If the size of the gap at both ends is different, the slurry flow rate will be different. Due to the low slurry flow rate in the tank with large gap, mineral sand deposition and even blockage may occur. When one end of the tank is blocked, the observed phenomenon is that the surface of the cylinder at the end of the block cannot absorb the concentrate.