1. When the PTMS magnetic separator transfers, we should carefully listen to the report on the operation of the office and make it clear.
2. Check whether the oil quantity of the reducer and other lubricating parts is enough and whether the oil quality meets the requirements. Fill with lubricating oil if necessary to maintain good lubrication.
3. Check whether the transmission chain is engaged correctly and the tightness is appropriate.
4, check the PTMS magnetic separator tank, pipeline, if there is debris blockage should be removed, dredge, damage should be timely reported and treated.
5, artificial turning check, magnetic drum should be flexible rotation, no friction phenomenon.
6. After the new installation or maintenance of the motor, it should be verified that the cylinder steering is correct before the first start. The rotating direction of the countercurrent type cylinder should be opposite to the feeding direction.
7. Check whether the PTMS magnetic separator control appliances, signals, protective cover, protective grounding and various bolts are complete, sound, tight and reliable.
8. Check the safety situation and hidden dangers on the site.
9. It is strictly prohibited to put steel or iron tools or materials near the magnetic roller during inspection to prevent them from being sucked and accidents.