PTMS magnetic separator must be started before the main belt is started. When stopping, it can be stopped only after the main belt material is pulled empty. The sucked iron should be recovered and cleaned in time. The detonator must be handed over to the workshop, and it is strictly prohibited to hide it. When the iron removal machine is running, it is forbidden to walk around the iron remover and the iron discharging port, stay or clean the iron to prevent the iron wounding.
It is necessary to check the operation of PTMS magnetic separator frequently during the working process. When abnormal phenomena such as tape deviation, joint clip opening and body sway are found, the machine must be shut down immediately and reported to the factory control room. The power supply must be cut off when the iron remover is faulty.
When driving on the spot, after receiving the PTMS magnetic separator stop signal, you can press the stop button to stop when there is no material on the equipment. Centralized control of driving, by the dispatch centralized control of parking. The work area should be cleaned before the shift, and all kinds of items should be neatly placed. The shift should be transferred on site, and the operation status, fault and problems of the PTMS magnetic separator of the current shift should be explained to the replacement personnel in detail. The shift log should be filled in carefully according to the requirements, and the shift transfer procedure can be completed before transfer